Standard
Elimination of autofluorescence background from fluorescence tissue images by use of time-gated detection and the AzaDiOxaTriAngulenium (ADOTA) fluorophore. / Rich, Ryan M.; Stankowska, Dorota L. ; Maliwal, Badri P.; Sørensen, Thomas Just; Laursen, Bo Wegge; Krishnamoorthy, Raghu R. ; Gryczynski, Zygmunt; Borejdo, Julian; Gryczynski, Ignacy; Fudala, Rafal.
I:
Analytical and Bioanalytical Chemistry, Bind 405, Nr. 6, 2013, s. 2065-2075.
Publikation: Bidrag til tidsskrift › Tidsskriftartikel › Forskning › fagfællebedømt
Harvard
Rich, RM, Stankowska, DL, Maliwal, BP
, Sørensen, TJ, Laursen, BW, Krishnamoorthy, RR, Gryczynski, Z, Borejdo, J, Gryczynski, I & Fudala, R 2013, '
Elimination of autofluorescence background from fluorescence tissue images by use of time-gated detection and the AzaDiOxaTriAngulenium (ADOTA) fluorophore',
Analytical and Bioanalytical Chemistry, bind 405, nr. 6, s. 2065-2075.
https://doi.org/10.1007/s00216-012-6623-1
APA
Rich, R. M., Stankowska, D. L., Maliwal, B. P.
, Sørensen, T. J., Laursen, B. W., Krishnamoorthy, R. R., Gryczynski, Z., Borejdo, J., Gryczynski, I., & Fudala, R. (2013).
Elimination of autofluorescence background from fluorescence tissue images by use of time-gated detection and the AzaDiOxaTriAngulenium (ADOTA) fluorophore.
Analytical and Bioanalytical Chemistry,
405(6), 2065-2075.
https://doi.org/10.1007/s00216-012-6623-1
Vancouver
Rich RM, Stankowska DL, Maliwal BP
, Sørensen TJ, Laursen BW, Krishnamoorthy RR o.a.
Elimination of autofluorescence background from fluorescence tissue images by use of time-gated detection and the AzaDiOxaTriAngulenium (ADOTA) fluorophore.
Analytical and Bioanalytical Chemistry. 2013;405(6):2065-2075.
https://doi.org/10.1007/s00216-012-6623-1
Author
Rich, Ryan M. ; Stankowska, Dorota L. ; Maliwal, Badri P. ; Sørensen, Thomas Just ; Laursen, Bo Wegge ; Krishnamoorthy, Raghu R. ; Gryczynski, Zygmunt ; Borejdo, Julian ; Gryczynski, Ignacy ; Fudala, Rafal. / Elimination of autofluorescence background from fluorescence tissue images by use of time-gated detection and the AzaDiOxaTriAngulenium (ADOTA) fluorophore. I: Analytical and Bioanalytical Chemistry. 2013 ; Bind 405, Nr. 6. s. 2065-2075.
Bibtex
@article{7fc72618aecb4bdeb1df19443ffecbc7,
title = "Elimination of autofluorescence background from fluorescence tissue images by use of time-gated detection and the AzaDiOxaTriAngulenium (ADOTA) fluorophore",
author = "Rich, {Ryan M.} and Stankowska, {Dorota L.} and Maliwal, {Badri P.} and S{\o}rensen, {Thomas Just} and Laursen, {Bo Wegge} and Krishnamoorthy, {Raghu R.} and Zygmunt Gryczynski and Julian Borejdo and Ignacy Gryczynski and Rafal Fudala",
year = "2013",
doi = "10.1007/s00216-012-6623-1",
language = "English",
volume = "405",
pages = "2065--2075",
journal = "Analytical and Bioanalytical Chemistry",
issn = "1618-2642",
publisher = "Springer",
number = "6",
}
RIS
TY - JOUR
T1 - Elimination of autofluorescence background from fluorescence tissue images by use of time-gated detection and the AzaDiOxaTriAngulenium (ADOTA) fluorophore
AU - Rich, Ryan M.
AU - Stankowska, Dorota L.
AU - Maliwal, Badri P.
AU - Sørensen, Thomas Just
AU - Laursen, Bo Wegge
AU - Krishnamoorthy, Raghu R.
AU - Gryczynski, Zygmunt
AU - Borejdo, Julian
AU - Gryczynski, Ignacy
AU - Fudala, Rafal
PY - 2013
Y1 - 2013
U2 - 10.1007/s00216-012-6623-1
DO - 10.1007/s00216-012-6623-1
M3 - Journal article
C2 - 23254457
VL - 405
SP - 2065
EP - 2075
JO - Analytical and Bioanalytical Chemistry
JF - Analytical and Bioanalytical Chemistry
SN - 1618-2642
IS - 6
ER -